Item No: M71907-- M71924

 

 

1. Core functions (direct role)

Insulation and anti-electric shock: The wrench body (except for the biting working surface) is wrapped in a high-voltage resistant insulating injection molding layer (common materials are nylon and epoxy resin), which can isolate AC/DC voltages of 1000V and above, prevent current from being conducted through the human body during operation, and reduce the risk of electric shock.

 

Quick tightening/disassembly: Open design (single or double heads, double heads are of different specifications), which can quickly insert the bolt/nut heads to adapt to space-limited scenarios (such as dense wiring), and efficiently complete tightening or disassembly operations.

 

Rust-proof and wear-resistant: The metal body is mostly forged from chromium-vanadium steel (Cr-V), which has high hardness and resistance to deformation. The insulation layer is closely attached, waterproof and corrosion-resistant, and is suitable for outdoor or humid operation (must meet IP protection level).

 

Specification adaptability: Common specifications cover M4-M32 (metric) and 1/4"-1 1/4"(imperial). Double-ended models can reduce the number of tools carried and meet the needs of fasteners of different specifications.

 

2. Main application scenarios (classified by field)

1. Power engineering/distribution maintenance (core scenarios)

High-voltage distribution room: Tighten/remove the distribution cabinet, connection terminal bolts and bus fixing nuts in the distribution cabinet (such as components in 10kV/35kV switch cabinets);

 

Outdoor power facilities: maintenance of connection bolts for utility poles, transformers, and transformers, installation and maintenance of overhead line fittings (such as strain clamps, insulators);

 

Low-voltage electrical system: Operation of fixing bolts for circuit breakers and contactors in distribution boxes and switch boxes in factory workshops and commercial buildings (to avoid accidental contact with live objects).

 

2. Electrical maintenance/home decoration, water and electricity

Indoor circuit renovation: When installing switches, sockets, and lamps, tighten the fixing bolts in the junction box (working close to live wires);

 

Home appliance repair: Removal of connecting terminals and compressor fixing bolts for air conditioners, refrigerators, washing machines and other electrical appliances (power is required but there is residual charge scenario);

 

Weak current engineering: The equipment wiring bolts of communication base stations and network computer rooms are tightened (to prevent tools from conducting electricity and damaging precision equipment).

 

3. Industrial equipment/automation scenarios

Electrical equipment assembly: Installation and debugging of motors, frequency converters, and PLC control cabinets, fastening of wiring terminals and grounding bolts;

 

Electrical maintenance of the production line: maintenance of electrical connecting parts of assembly line equipment and robots (emergency treatment when the equipment is running live must comply with safety regulations);

 

Operation in explosion-proof environment: Some insulation wrenches with explosion-proof grade (such as Ex ia IIB T4) are suitable for electrical maintenance in flammable and explosive places such as chemicals and mines (to avoid sparks + prevent electric shock).

 

4. New energy field (emerging high-frequency scenarios)

Photovoltaic power station: installation and maintenance of solar panel bracket fixing bolts and inverter terminal (outdoor live work requires insulation + corrosion protection);

 

New energy vehicles: Tighten the internal connection bolts of the charging pile, maintain the external electrical components of the battery pack (for high-voltage system operations, it must comply with HVIL insulation standards);

 

Energy storage equipment: wiring bolt operation for energy storage battery cabinet and PCS energy storage converter (in high-voltage DC scenarios, insulation level needs to be adapted to 1500V DC).

 

3. Suggestions for selection and use adaptation (suitable for maintenance/procurement needs)

Key indicators of selection:

Insulation level: Priority is given to IEC 60900 Class 00/0/1/2 (corresponding to rated voltage 500V/1000V/1500V/3000V), 1000V (Class 1) for daily electrical maintenance, and 1500V and above for high-voltage operations;

Material: Metal body Cr-V steel (hardness ≥HRC45), insulation layer has no cracks or bubbles, and complies with RoHS environmental standards;

Specifications: M4-M14 set is selected for household/weak current maintenance, M8-M24 single-head/dual-head combination is selected for power engineering, and special specifications for high-voltage scenarios (such as M10-M18) are selected for new energy fields.

 

Common compliance model references:

Household/light electrician: Shida SATA 96601 (insulated open-ended wrench set, 1000V, M5-M14);

Power Engineering: Stanley STMT74864 -8-23 (double-ended insulated open-ended wrench, 1500V, M8-M22);

Special for new energy: Wurth 715511 (high-voltage insulated open-ended wrench, 1500V DC, suitable for new energy vehicles/photovoltaic equipment).

 

Precautions for use:

Check whether the insulation layer is damaged or aged before operation, and it is prohibited to use it in insulation failure or humid environments (such as rain);

Only suitable for tightening/removing hexagon bolts/nuts, avoid using round-head and severely worn fasteners (to prevent slipping);

Strictly follow the live working procedures, use only within the rated voltage range, and cannot replace other protective equipment such as insulating gloves and insulating shoes.

product-845-572

 

Our Service

product-839-603One-stop tool solutions- OEM Business and Our Own Brand development Basing on more than 54-year professional production and sales experience, expertise and commitment in delivering professional quality service to world-wide customer base, Maxpower is your reliable partner always!

 

Skilled Sales Team and Expert Team

Maxpower skilled sales team has undergone Industrial's technical training and business experience. We will definitely provide professional service to respond customers' demands.

 

Expert Team, Technical Support

We have established two teams of production and engineering technology to coordinate all resources to achieve enterprise innovation and build a smart manufacturing factory. Our vision is to grow with end customers, achieve long-term operations, create one-stop tool solutions for customers, and create new value-added highlights for customers in accordance with lean thinking.

Send Inquiry

whatsapp

Phone

E-mail

Inquiry